SAFETY LEVEL

Defines the self-monitoring and safety principles contained in the device; it must be chosen as a function of the risk level characterising the machine.

PROTECTED HEIGHT

This is the height protected by the light curtain. If it is positioned horizontally, this value shows the depth of the protected zone.

RANGE

This is the maximum working distance that may exist between the emitter and the receiver.

RESPONSE TIME

This is the time it takes for the safety light curtain to transmit the alarm signal from the time the protected zone is interrupted.

LIGHT CURTAIN RESOLUTION

The resolution of a light curtain is the minimum size of an object that, placed into the controlled area, will obscure the controlled zone and hence stop the hazardous movement of the machine.

2386 products

  • Placeholder
    1110054

    EOS4 1803 XH WTF – 1110054

    Hand Detection Safety Light Curtain with Watertight Enclosure, IP69K/Ecolab Certified, Automatic/Manual Restart and EDM, Prewired with 10 m Lead Cable

  • Placeholder
    1110058

    EOS4 1803 XH WTHF – 1110058

    Hand Detection Safety Light Curtain with Heated Watertight Enclosure, IP69K/Ecolab Certified, Automatic/Manual Restart and EDM, Prewired with 10 m Lead Cable

  • Placeholder
    1310275

    EOS4 1803 XM – 1310275

    Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Master)

  • Placeholder
    1310277

    EOS4 1803 XS – 1310277

    Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Primary Slave)

  • Placeholder
    1310279

    EOS4 1803 XS2 – 1310279

    Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Secondary Slave)

  • Placeholder
    1310832

    EOS4 1803 XT – 1310832

    Hand Detection Safety Light Curtain with Automatic/Manual Restart and EDM, Resistant to High Vibrations

  • Placeholder
    1310371

    EOS4 1804 A – 1310371

    Hand Detection Safety Light Curtain with Automatic Restart

  • Placeholder
    1310381

    EOS4 1804 AH – 1310381

    Hand Detection Safety Light Curtain with Automatic Restart, Extended Range

  • Placeholder
    1310373

    EOS4 1804 X – 1310373

    Hand Detection Safety Light Curtain with Automatic/Manual Restart and EDM

  • Placeholder
    1310383

    EOS4 1804 XH – 1310383

    Hand Detection Safety Light Curtain with Automatic/Manual Restart and EDM, Extended Range

  • Placeholder
    1310375

    EOS4 1804 XM – 1310375

    Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Master)

  • Placeholder
    1310377

    EOS4 1804 XS – 1310377

    Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Primary Slave)

  • Placeholder
    1310379

    EOS4 1804 XS2 – 1310379

    Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Secondary Slave)

  • Placeholder
    1310471

    EOS4 1805 A – 1310471

    Body Detection Safety Light Curtain with Automatic Restart

  • Placeholder
    1310481

    EOS4 1805 AH – 1310481

    Body Detection Safety Light Curtain with Automatic Restart, Extended Range

  • Placeholder
    1310473

    EOS4 1805 X – 1310473

    Body Detection Safety Light Curtain with Automatic/Manual Restart and EDM

  • Placeholder
    1310483

    EOS4 1805 XH – 1310483

    Body Detection Safety Light Curtain with Automatic/Manual Restart and EDM, Extended Range

  • Placeholder
    1310475

    EOS4 1805 XM – 1310475

    Body Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Master)

  • Placeholder
    1310477

    EOS4 1805 XS – 1310477

    Body Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Primary Slave)

  • Placeholder
    1310479

    EOS4 1805 XS2 – 1310479

    Body Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Secondary Slave)