SAFETY LEVEL
Defines the self-monitoring and safety principles contained in the device; it must be chosen as a function of the risk level characterising the machine.
PROTECTED HEIGHT
This is the height protected by the light curtain. If it is positioned horizontally, this value shows the depth of the protected zone.
RANGE
This is the maximum working distance that may exist between the emitter and the receiver.
RESPONSE TIME
This is the time it takes for the safety light curtain to transmit the alarm signal from the time the protected zone is interrupted.
LIGHT CURTAIN RESOLUTION
The resolution of a light curtain is the minimum size of an object that, placed into the controlled area, will obscure the controlled zone and hence stop the hazardous movement of the machine.
2386 products
-
1334141AX 302S – 1334141
Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Slave)
-
1334201AX 303 – 1334201
Hand Detection Safety Light Curtain with Automatic/Manual Restart and EDM
-
1334221AX 303M – 1334221
Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Master)
-
1334241AX 303S – 1334241
Hand Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Slave)
-
1334301AX 304 – 1334301
Hand Detection Safety Light Curtain with Automatic/Manual Restart and EDM
-
1334361AX 304BK – 1334361
Hand Detection Safety Light Curtain with Blanking Function, Automatic/Manual Restart and EDM
-
1334401AX 305 – 1334401
Body Detection Safety Light Curtain with Automatic/Manual Restart and EDM
-
1334421AX 305M – 1334421
Body Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Master)
-
1334441AX 305S – 1334441
Body Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Slave)
-
1334501AX 309 – 1334501
Body Detection Safety Light Curtain with Automatic/Manual Restart and EDM
-
1334601AX 3B – 1334601
Access Control Safety Light Grid with Automatic/Manual Restart and EDM
-
1334604AX 3B LR – 1334604
Access Control Safety Light Grid with Automatic/Manual Restart and EDM, Long Range
-
1334607AX 3B LR DB – 1334607
Access Control Safety Light Grid with Automatic/Manual Restart and EDM, Long Range, Dual-Beam Technology
-
1139607AX 3B LR DB WTH – 1139607
Safety Light Curtain with Heated Watertight Enclosure, Automatic/Manual Restart and EDM, Long Range with Dual-Beam Technology, IP67, Prewired with 10m Lead Cable
-
1134604AX 3B LR WT – 1134604
Safety Light Curtain with Watertight Enclosure, Automatic/Manual Restart and EDM, Long Range, IP67, Prewired with 10 m Lead Cable
-
1139604AX 3B LR WTH – 1139604
Safety Light Curtain with Heated Watertight Enclosure, Automatic/Manual Restart and EDM, Long Range, IP67, Prewired with 10 m Lead Cable
-
1334621AX 3BM – 1334621
Access Control Safety Light Grid for Cascading Connection with Automatic/Manual Restart and EDM (Master)
-
1334641AX 3BS – 1334641
Access Control Safety Light Grid for Cascading Connection with Automatic/Manual Restart and EDM (Slave)
-
1334002AX 451 – 1334002
Finger Detection Safety Light Curtain with Automatic/Manual Restart and EDM
-
1334062AX 451BK – 1334062
Finger Detection Safety Light Curtain with Blanking Function, Automatic/Manual Restart and EDM


