SAFETY LEVEL
Defines the self-monitoring and safety principles contained in the device; it must be chosen as a function of the risk level characterising the machine.
PROTECTED HEIGHT
This is the height protected by the light curtain. If it is positioned horizontally, this value shows the depth of the protected zone.
RANGE
This is the maximum working distance that may exist between the emitter and the receiver.
RESPONSE TIME
This is the time it takes for the safety light curtain to transmit the alarm signal from the time the protected zone is interrupted.
LIGHT CURTAIN RESOLUTION
The resolution of a light curtain is the minimum size of an object that, placed into the controlled area, will obscure the controlled zone and hence stop the hazardous movement of the machine.
2386 products
-
1310662EOS4 4B XH – 1310662
Access Control Safety Light Grid with Automatic/Manual Restart and EDM, Extended Range
-
1110672EOS4 4B XH WTF – 1110672
Access Control Safety Light Grid with Watertight Enclosure, IP69K/Ecolab Certified, Automatic/Manual Restart and EDM, Prewired with 10 m Lead Cable
-
1110677EOS4 4B XH WTHF – 1110677
Access Control Safety Light Grid with Heated Watertight Enclosure, IP69K/Ecolab Certified, Automatic/Manual Restart and EDM, Prewired with 10 m Lead Cable
-
1310622EOS4 4B XM – 1310622
Access Control Safety Light Grid for Cascading Connection with Automatic/Manual Restart and EDM (Master)
-
1310632EOS4 4B XS – 1310632
Access Control Safety Light Grid for Cascading Connection with Automatic/Manual Restart and EDM (Primary Slave)
-
1310642EOS4 4B XS2 – 1310642
Access Control Safety Light Grid for Cascading Connection with Automatic/Manual Restart and EDM (Secondary Slave)
-
1310003EOS4 601 A – 1310003
Finger Detection Safety Light Curtain with Automatic Restart
-
1310013EOS4 601 X – 1310013
Finger Detection Safety Light Curtain with Automatic/Manual Restart and EDM
-
1110033EOS4 601 X WTF – 1110033
Finger Detection Safety Light Curtain with Watertight Enclosure, IP69K/Ecolab Certified, Automatic/Manual Restart and EDM, Prewired with 10 m Lead Cable
-
1110043EOS4 601 X WTHF – 1110043
Finger Detection Safety Light Curtain with Heated Watertight Enclosure, IP69K/Ecolab Certified, Automatic/Manual Restart and EDM, Prewired with 10 m Lead Cable
-
1310023EOS4 601 XM – 1310023
Finger Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Master)
-
1310033EOS4 601 XS – 1310033
Finger Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Primary Slave)
-
1310043EOS4 601 XS2 – 1310043
Finger Detection Safety Light Curtain for Cascading Connection with Automatic/Manual Restart and EDM (Secondary Slave)
-
1310853EOS4 601 XT – 1310853
Finger Detection Safety Light Curtain with Automatic/Manual Restart and EDM, Resistant to High Vibrations
-
1310153EOS4 602 AH – 1310153
Hand Detection Safety Light Curtain with Automatic Restart, Extended Range
-
1310163EOS4 602 XH – 1310163
Hand Detection Safety Light Curtain with Automatic/Manual Restart and EDM, Extended Range
-
1310203EOS4 603 A – 1310203
Hand Detection Safety Light Curtain with Automatic Restart
-
1310253EOS4 603 AH – 1310253
Hand Detection Safety Light Curtain with Automatic Restart, Extended Range
-
1010253EOS4 603 AH EX – 1010253
Access Control Safety Light Grid with ATEX Zone 2/22 Enclosure, Automatic Restart, Extended Range, Prewired with 10 m Lead Cable
-
1310824EOS4 603 AT – 1310824
Hand Detection Safety Light Curtain with Automatic Restart, Resistant to High Vibrations


