383 tuotetta
-
0050801BA9094 – 0050801
BA9094.20 AC50/60HZ 110V P1=20-100C
2 PT1 inputs
Common changeover and make contact for P1, P2
Response and release values adjustable -
0051047BA9094 – 0051047
BA9094.20/001 AC230V P1=155C/145C
2 PT1 inputs
Common changeover and make contact for P1, P2
Response and dropout values are determined -
0051184BA9094 – 0051184
BA9094.20/001 AC110V P1=90C/80C
2 PT1 inputs
Common changeover and make contact for P1, P2
Response and dropout values are determined -
0051199BA9094 – 0051199
BA9094.28 DC24V P1=100-200C
2 PT1 inputs
1 changeover contact for P1
1 closer for P2
Response and release values adjustable -
0051419BA9094 – 0051419
BA9094.28/001 AC230V P1=110C/100C
2 PT1 inputs
1 changeover contact for P1
1 closer for P2
Response and dropout values are determined -
0051431BA9094 – 0051431
BA9094.28/001 AC230V P1=135C/125C
2 PT1 inputs
1 changeover contact for P1
1 closer for P2
Response and dropout values are determined -
0051550BA9094 – 0051550
BA9094.20 DC24V P1=20-100C
2 PT1 inputs
Common changeover and make contact for P1, P2
Response and release values adjustable -
0051560BA9094 – 0051560
BA9094.28 AC50/60HZ230V P1=220-350C
2 PT1 inputs
1 changeover contact for P1
1 closer for P2
Response and release values adjustable -
0051710BA9094 – 0051710
BA9094.28 DC24V P1=20-100C
2 PT1 inputs
1 changeover contact for P1
1 closer for P2
Response and release values adjustable -
0051776BA9094 – 0051776
BA9094.20/001 DC24V P1=160C/150C
2 PT1 inputs
Common changeover and make contact for P1, P2
Response and dropout values are determined -
0052392BA9094 – 0052392
BA9094.28 AC50/60HZ 230V P1=60-150C
2 PT1 inputs
1 changeover contact for P1
1 closer for P2
Response and release values adjustable -
0052737BA9094 – 0052737
BA9094.20 DC24V P1=60-150C
2 PT1 inputs
Common changeover and make contact for P1, P2
Response and release values adjustable -
0052791BA9094 – 0052791
BA9094.20 AC50/60HZ 240V P1=20-100C
2 PT1 inputs
Common changeover and make contact for P1, P2
Response and release values adjustable -
0053278BA9094 – 0053278
BA9094.28/100 AC110V P1=60-150C
1 PT1 input
2 exits
Response and release values can be set separately for each output -
0053901BA9094 – 0053901
BA9094.28 AC50/60HZ230V P1=140-250C
2 PT1 inputs
1 changeover contact for P1
1 closer for P2
Response and release values adjustable -
0053961BA9094 – 0053961
BA9094.20 AC50/60HZ230V P1=100-200C
2 PT1 inputs
Common changeover and make contact for P1, P2
Response and release values adjustable -
0054041BA9094 – 0054041
BA9094.28/001 AC230V P1=110C/100C
2 PT1 inputs
1 changeover contact for P1
1 closer for P2
Response and dropout values are determined -
0054332BA9094 – 0054332
BA9094.28/100 AC240V P1=20-100C
1 PT1 input
2 exits
Response and release values can be set separately for each output -
0054453BA9094 – 0054453
BA9094.28/100 DC24V P1=20-100C
1 PT1 input
2 exits
Response and release values can be set separately for each output -
0054506BA9094 – 0054506
BA9094.28/100 AC110V P1=20-100C
1 PT1 input
2 exits
Response and release values can be set separately for each output